3-(二甲氨基)吡咯烷, 99%,3-(Dimethylamino)pyrrolidine

产品编号:西域试剂-WR132917| CAS NO:69478-75-7| MDL NO:MFCD01569246| 分子式:C6H14N2| 分子量:114.19

本网站销售的所有产品仅用于工业应用或者科学研究等非医疗目的,不可用于人类或动物的临床诊断或者治疗,非药用,非食用,

货号 包装 价格 库存与货期 购买量 操作
西域试剂-WR132917
186.00 杭州 北京(现货)
西域试剂-WR132917
608.00 杭州 北京(现货)
西域试剂-WR132917
2730.00 杭州 北京(现货)

增值税发票√顺丰快递√订货电话:18601927057

英文名称3-(Dimethylamino)pyrrolidine
CAS编号69478-75-7
产品沸点157.6±8.0 °C at 760 mmHg
产品密度0.9±0.1 g/cm3
产品闪点54.5±9.4 °C
精确质量114.115700
PSA15.27000
LogP-0.42
外观性状液体;Colorless to Light yellow clear liquid
蒸气压2.7±0.3 mmHg at 25°C
折射率1.481
稳定性

远离氧化物,热和光。

储存条件

存放在密封容器内,并放在阴凉,干燥处。储存的地方必须远离氧化剂,远离水源,热。

相关文档

化学品安全说明书(MSDS)

下载MSDS

质检证书(COA)

相关产品


危害码 (欧洲) Xn
风险声明 (欧洲) R10
安全声明 (欧洲) S26-S36-S37-S39
危险品运输编码 UN 2734
海关编码 2933990090
3-(Dimethylamino)pyrrolidine Revision number: 5
SAFETY DATA SHEET

Section1. IDENTIFICATION
Product name:3-(Dimethylamino)pyrrolidine

Revision number:5

Section2. HAZARDS IDENTIFICATION
GHS classification
PHYSICAL HAZARDS
Category 3
Flammable liquids
HEALTH HAZARDS
Category 1B
Skin corrosion/irritation
Serious eye damage/eye irritationCategory 1
Not classified
ENVIRONMENTAL HAZARDS
GHS label elements, including precautionary statements
Pictograms or hazard symbols
Signal wordDanger
Hazard statementsFlammable liquid and vapour
Causes severe skin burns and eye damage
Precautionary statements:
[Prevention]Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
Keep container tightly closed.
Use explosion-proof electrical/ventilating/lighting equipment. Take precautionary
measures against ignition by the static discharge and the spark.
Do not breathe dust/fume/gas/mist/vapours/spray.
Wash hands thoroughly after handling.
Wear protective gloves/eye protection/face protection.
IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for
[Response]
breathing.
IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses,
if present and easy to do. Continue rinsing.
IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse
skin with water/shower.
Wash contaminated clothing before reuse.
Immediately call a POISON CENTER or doctor/physician.
[Storage]Store in a well-ventilated place. Keep cool.
Store locked up.
[Disposal]Dispose of contents/container through a waste management company authorized by
the local government.
3-(Dimethylamino)pyrrolidine

Section3. COMPOSITION/INFORMATION ON INGREDIENTS
Substance/mixture:Substance
Components:3-(Dimethylamino)pyrrolidine
Percent:>98.0%(GC)(T)
CAS Number:69478-75-7
Chemical Formula:C6H14N2

Section4. FIRST AID MEASURES
Remove victim to fresh air and keep at rest in a position comfortable for breathing.
Inhalation:
Immediately call a POISON CENTER or doctor/physician.
Skin contact:Remove/Take off immediately all contaminated clothing. Gently wash with plenty of
soap and water. Immediately call a POISON CENTER or doctor/physician.
Eye contact:Rinse cautiously with water for several minutes. Remove contact lenses, if present
and easy to do. Continue rinsing.Immediately call a POISON CENTER or
doctor/physician.
Ingestion:Immediately call a POISON CENTER or doctor/physician. Rinse mouth. Do NOT
induce vomiting.
A rescuer should wear personal protective equipment, such as rubber gloves and air-
Protection of first-aiders:
tight goggles.

Section5. FIRE-FIGHTING MEASURES
Suitable extinguishingDry chemical, foam, carbon dioxide.
media:
Unsuitable extinguishing Water (It may scatter and spread fire.)
media:
Specific hazards arising Take care as it may decompose upon combustion or in high temperatures to
from the chemical:generate poisonous fume.
Precautions for firefighters: Fire-extinguishing work is done from the windward and the suitable fire-extinguishing
method according to the surrounding situation is used. Uninvolved persons should
evacuate to a safe place. In case of fire in the surroundings: Keep containers cool by
spraying with water. Eliminate all ignition sources if safe to do so.
Special protectiveWhen extinguishing fire, be sure to wear personal protective equipment.
equipment for firefighters:

Section6. ACCIDENTAL RELEASE MEASURES
Personal precautions,Use extra personal protective equipment (self-contained breathing apparatus). Keep
protective equipment and people away from and upwind of spill/leak. Ensure adequate ventilation. Entry to non-
emergency procedures: involved personnel should be controlled around the leakage area by roping off, etc.
Environmental precautions: Prevent product from entering drains.
Methods and materials for Absorb spilled material in dry sand or inert absorbent before recovering it into an
containment and cleaning airtight container. In case of large amount of spillage, contain a spill by bunding.
up: Adhered or collected material should be promptly disposed of, in accordance with
appropriate laws and regulations.
Prevention of secondary Remove all sources of ignition. Fire-extinguishing devices should be prepared in
hazards:case of a fire. Use spark-proof tools and explosion-proof equipment.

Section7. HANDLING AND STORAGE
Precautions for safe handling
Technical measures:Handling is performed in a well ventilated place. Wear suitable protective equipment.
Prevent generation of vapour or mist. Keep away from heat/sparks/open flame/hot
surfaces. -No smoking. Take measures to prevent the build up of electrostatic
charge. Use explosion-proof equipment. Wash hands and face thoroughly after
handling.
Use a closed system if possible. Use a ventilation, local exhaust if vapour or aerosol
will be generated.
Avoid contact with skin, eyes and clothing.
Advice on safe handling:
3-(Dimethylamino)pyrrolidine

Section7. HANDLING AND STORAGE
Conditions for safe storage, including any
incompatibilities
Storage conditions:Keep container tightly closed. Store in a cool, dark and well-ventilated place.
Store under inert gas.
Store locked up.
Store away from incompatible materials such as oxidizing agents.
Air-sensitive
Packaging material:Comply with laws.

Section8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Install a closed system or local exhaust. Also install safety shower and eye bath.
Engineering controls:
Personal protective equipment
Respiratory protection: Half or full facepiece respirator, self-contained breathing apparatus(SCBA), supplied
air respirator, etc. Use respirators approved under appropriate government standards
and follow local and national regulations.
Hand protection:Impervious gloves.
Safety goggles. A face-shield, if the situation requires.
Eye protection:
Skin and body protection: Impervious protective clothing. Protective boots, if the situation requires.

Section9. PHYSICAL AND CHEMICAL PROPERTIES
Liquid
Physical state (20°C):
Form:Clear
Colour:Colorless - Slightly pale yellow
No data available
Odour:
pH: No data available
Melting point/freezing point:No data available
Boiling point/range:164°C
No data available
Flash point:
Flammability or explosive
limits:
Lower:No data available
No data available
Upper:
Relative density:0.91
Solubility(ies):
[Water]No data available
No data available
[Other solvents]

Section10. STABILITY AND REACTIVITY
Chemical stability:Stable under proper conditions.
Possibility of hazardous No special reactivity has been reported.
reactions:
Conditions to avoid:Spark, Open flame, Static discharge
Incompatible materials: Oxidizing agents, Acids
Hazardous decomposition Carbon monoxide, Carbon dioxide, Nitrogen oxides (NOx)
products:

Section11. TOXICOLOGICAL INFORMATION
Acute Toxicity:No data available
Skin corrosion/irritation: No data available
Serious eyeNo data available
damage/irritation:
Germ cell mutagenicity: No data available
Carcinogenicity:
IARC =No data available
No data available
NTP =
Reproductive toxicity:No data available
3-(Dimethylamino)pyrrolidine

Section12. ECOLOGICAL INFORMATION
Ecotoxicity:
Fish:No data available
Crustacea:No data available
Algae:No data available
Persistence / degradability: No data available
BioaccumulativeNo data available
potential(BCF):
Mobility in soil
No data available
Log Pow:
Soil adsorption (Koc):No data available
Henry's LawNo data available
constant(PaM3/mol):

Section13. DISPOSAL CONSIDERATIONS
Recycle to process, if possible. Consult your local regional authorities. You may be able to burn in a chemical
incinerator equipped with an afterburner and scrubber system. Observe all federal, state and local regulations when
disposing of the substance.

Section14. TRANSPORT INFORMATION
8: Corrosive.
Hazards Class:
Subsidiary risk:3: Flammable liquid.
UN-No:2734
Proper shipping name:Polyamines, liquid, corrosive, flammable, n.o.s.
Packing group:II

Section15. REGULATORY INFORMATION
Safe management ordinance of dangerous chemical product (State Council announces on January 26, 2002
and revised on February 16,2011): Safe use and production, the storage of a dangerous chemical, transport,
loading and unloading were prescribed.


SECTION 16 - ADDITIONAL INFORMATION
N/A
上游产品  0

下游产品  3

服务热线

13911702513
18601927057

微信客服